718 REFERENCES Garnier, P., et al., 1998, “Dual‐Energy Synchrotron X-Ray Measurements of Rapid Soil Density and Water Content Changes in Swelling Soils During Infiltration,” Water Resources Research, vol. 34, no. 11: 2837-2842. Geddes, C., B. Ludewigt, J. Valentine, B. Quiter, M. Descalle, G. Warren, M. Kinlaw, S. Thompson, D. Chichester, C. Miller, and S. Pozzi, 2017, Impact of Monoenergetic Photon Sources on Non- proliferation Applications, Idaho National Laboratory, Idaho Falls, ID. Haff, R.P. and N. Toyofuku, 2008, “X-Ray Detection of Defects and Contaminants in the Food Industry,” Sensing and Instrumentation Food Quality, 2:262–273. Huddleston, A. and J. Sackler, 1985, “Determination of Electron Density by the DualEnergy Compton Scatter Method.” Medical Physics. vol. 12. New York, NY: American Institute of Physics, for the American Association of Physicists in Medicine: 1319. Hull, M., 2017, “Accuracy, Precision and Confidence in X-ray Fluorescence for Positive Material Identification”. The NDT Technician, vol 16, no. 1, Columbus, OH: American Society for Nondestructive Testing. IUCr , 1999, “International Tables for X-ray Crystallography,” Vol. C: Mathematical, Physical and Chemical Tables. International Union of Crystallography, Dordrecht, Netherlands: Kluwer Academic Publishers. Jamet, F. and G. Thomer, 1976, Flash Radiography, Elsevier Publishing Company. Kim, N. and J. Achenbach, 1998, “Quantitative Characterization of Multiple Delaminations in Laminated Composites Using the Compton Backscatter Technique,” Journal of Nondestructive Evaluation. vol. 17. New York, NY: Plenum: 5365. Kosanetzky, J.M., G. Harding, K.H. Fischer and A. Meyer, 1988, Compton Backscatter Tomography of Low Atomic Number Materials with the ComScan System. Philips Technical Information Bulletin. Hamburg, Germany: Philips GmbH. Kosanetzky, J.M., ca. 1990, “Inspection of the Pressure Bulkhead of an Aircraft,” ComScan Application Note. Hamburg, Germany: Philips GmbH. Landolt, J.F., W.D. Stump and J.L. Summers, 1978, “A Visual Comparative Method for Radiographic Determination of Defect Thickness.” Materials Evaluation. vol. 36, No. 11. Columbus, OH: American Society for Nondestructive Testing (October): 33. Lawson, L., 1993, “Flux Maximization Techniques for Compton Backscatter Depth Profilometry.” Journal of X-ray Science and Technology, vol. 4: Amsterdam, Netherlands: IOS Press: 1836. Lawson, L., 1995, “Compton X-ray Backscatter Depth Profilometry for Aircraft Corrosion Inspection.” Materials Evaluation. vol. 53, no. 8. Columbus, OH: American Society for Nondestructive Testing (August): 936941. Lawson, L., 2001, X-ray Backscattering, Final Report, National Aging Aircraft Research Program (NAARP), NDI 4, Subtask D, Radiographic Methods for Corrosion Inspection. Washington, DC: Federal Aviation Administration. Lehmann, L.A., R.E. Alvarez, A. Macovski, W.R. Brody, N.J. Pelc, S.J. Riederer, and A.L. Hall, 1981, “Generalized Image Combinations in Dual KVP Digital Radiography,” Medical Physics, vol. 8, no. 5: 659- 667. Liu, Y., et al., 2008, “Comparison of Neutron and High-energy X-Ray Dual-beam Radiography for Air Cargo Inspection,” Applied Radiation and Isotopes, vol. 66, no 4: 463-473. Lipton, L., 1997a, Stereo-Vision Formats for Video and Computer Graphics, White paper. San Rafael, CA: StereoGraphics Corporation. Lipton, L., 1997b, StereoGraphics Developers’ Handbook. San Rafael, CA: StereoGraphics Corporation. Lipton, L., 2000, “A Little History and HP’s Link to Stereoscopic Visualization,” The HP Chronicle, Austin, TX: Publications and Communications (March). Lipton, L. and M. Feldman, 2001, A New Autostereoscopic Display Technology: The SynthaGram™,White paper. San Rafael, CA: StereoGraphics. Liu, Y., et al., 2008, “Comparison of Neutron and High-energy X-Ray Dual-beam Radiography For Air Cargo Inspection,” Applied Radiation and Isotopes, vol. 66, no 4: 463-473. Lockwood, G., S.L. Shope, J.C. Wehlberg, M.M. Selph, J.M. Jojola, B.N. Turman and J.A. Jacobs, 1998, “Field Tests of Xray Backscatter Mine Detection.” Proceedings of the 2nd International Conference on the Detection of Abandoned Land Mines (Edinburgh, United Kingdom). IEE Conference Publication No. 458. Stevenage, United Kingdom: Institute of Electrical Engineers: 160163. MacKenzie, I.K., 1999, Method and Apparatus for Measuring Thickness of Paint Layers on Substrates Using Backscattered X-rays, US Patent 5862199, filed 29 July 1997, and issued 19 January 1999. Marilleau, J., ed., 1981, Proceedings of the First European Conference on Cineradiography with Photons or Particles (Paris) Bellingham, WA: International Society for Optical Engineering. Martin, L., W.C. Karl, and P. Ishwar, 2014, “Artifact Reduction in Dual-Energy CT Reconstruction For Security Applications,” Third International Conference on Image Formation in X-ray Computed Tomography: 133-136, (June). Martz, Jr., H.E., G.P. Roberson, D.J. Schneberk, and S.G. Azevedo, 1991, “Nuclear-Spectroscopy-Based, First-Generation, Computerized Tomography Scanners,” IEEE Transactions on Nuclear Science, vol. 38: 623. Martz, Jr., H.E., G.P. Roberson, M.F. Skeate, D.J. Schneberk, and S.G. Azevedo, 1991a, “Computed Tomography Studies of Concrete Samples,” Nuclear Instruments Methods in Physics, vol. B58: 216. Martz, H.E., D.J. Schneberk, S.G. Azevedo, and S.K. Lynch, 1991b, “Computerized Tomography of High Explosives, Nondestructive Characterization of Materials IV, Plenum Press, NY: 187-195. Martz, Jr., H.E., and C.R. Crawford, 2009, “Overview of Deployed EDS Technologies,” Report LLNL-TR-417232, Lawrence Livermore National Laboratory, Livermore, CA. Martz, Jr., Harry E., Clint M. Logan, Daniel J. Schneberk and Pete J. Shull, 2017, X-ray Imaging: Fundamentals, Industrial Techniques and Applications, CRC Press, Boca Raton, FL. Martz, H., et al., 2017a, “Poly- versus Mono-energetic Dual-spectrum Non-intrusive Inspection of Cargo Containers,” IEEE Transactions on Nuclear Science, vol. 64, no. 7. Merkle, A., & Gelb, J., 2013, “The Ascent of 3D X-ray Microscopy in the Laboratory.” Microscopy Today, 21(2), 10-15. doi:10.1017/ S1551929513000060. Midcoast Aviation 1999, “Midcoast Purchases ComScan 160 II X-ray System to Complete Gulfstream 580 Bulkhead Inspections.” May Press release. Saint Louis, MO. NACE International, 1960, “The Analysis and Composition of Aluminum Corrosion Products.” NACE Publication 605. Annual Conference: Corrosion. vol. 16. Houston, TX: 181t187t. Nishitani, H. et al., 1986, “Dual-energy Projection Radiography Using Condenser X-Ray Generator and Digital Radiography Apparatus,” Radiology vol. 161 no. 2: 533-535. Ogorodnikov, S., et al., 2002, “Radioscopic Discrimination of Materials in the 1-10 MeV Range for Customs Applications,” Proceedings of EPAC, Paris: 2807-2809. Ong, P.S., W.L. Anderson, B.D. Cook and R. Subramanyan, 1993, “Transcatter X-ray Technique for the Inspection of Insulated, OilCarrying Pipelines.” Review of Progress in Quantitative Nondestructive Evaluation. vol. 12. New York, NY: Plenum: 295301.
719 Perisinakas, K., 2018, “Dual Energy Computed Tomography,” Handbook of X-ray Imaging Physics and Technology, CRC Press, Boca Raton, FL. Petersilka, M., et al., 2008, “Technical Principles of Dual Source CT,” European Journal of Radiology, vol. 68: 362–368. Pincus, C., et al., 2011, Technical Advice and Support for the Cargo Advanced Automated Radiography System (CAARS) Program, Domestic Nuclear Detection Office, LLNL-TR-473131. Rao, A. Gourav, V. P. Deshmukh, Leah L. Lavery, Hrishikesh Bale, 2017, “3D Investigation of the Microstructural Modification in Hypereutectic Aluminum Silicon (Al-30Si) alloy,” Microscopy and Microanalysis, 8 June. Rebuffel, V., and J.M. Dinten, 2007, “Dual-energy X-ray imaging: benefits and limits,” Non-Destructive Testing and Condition Monitoring, 49 (10): 589-594(6). Roder, F.L., 1979, “Explosives Detection by Dual-Energy Computed Tomography (CT),” Proceedings SPIE 0182: Imaging Applications for Automated Industrial Inspection and Assembly, (10 October) doi: 10.1117/12.957385. Roye, W., 1991, “The Reliability of Nondestructive Techniques within the Field of Modern Composite Materials.” British Journal of NonDestructive Testing. vol. 33, No. 11. Northampton, United Kingdom: British Institute of NonDestructive Testing (November): 549550. SAE International, 2003, Residual Stress Measurement by X-ray Diffraction, HS-784, Warrendale, PA. Saverskiy, A., 2015, et al., “Cargo and Container X-ray Inspection with Intra-Pulse Multi-Energy Method for Material Discrimination,” Physics Procedia, vol. 66, pp 232-241. Schach. A., et al., 2002, “Blurring Artifacts in Megavoltage Radiography with a Flat-Panel Imaging System: Comparison of Monte Carlo Simulations with Measurements,” Medical Physics, vol. 29, no. 11, pp 2559-2570. Schulte, R.L., 1998, Two-Dimensional Imaging Backscatter Probe. US Patent 5763886, filed 7 August 1996, and issued 9 June 1998. Stokes, J.A., K.R. Alvar, R.L. Corey, D.G. Costello, J. John, S. Kocimski, N.A. Lurie, D.D. Thayer, A.P. Trippe and J.C. Young, 1982, “Some New Applications of Collimated Photon Scattering for Nondestructive Examination.” Nuclear Instruments and Methods. vol. 193. Amsterdam, Netherlands: North Holland Publishing Company: p 261267. Strecker, H., 1982, “Scatter Imaging of Aluminum Castings Using an X-ray Fan Beam and a Pinhole Camera.” Materials Evaluation. vol. 40, No. 10. Columbus, OH: American Society for Nondestructive Testing (September): 10501056. Su, Z., A. Jacobs, E.T. Dugan, J. Howley and J. Jacobs, 2000, “Lateral Migration Radiography, Application to Land Mine Detection and Classification.” Optical Engineering. vol. 39. Bellingham, WA: International Society for Optical Engineering: 24722479. Taylor, M.L., R.L. Smith, F. Dossing and R.D. Franich, 2012, “Robust Calculation of Effective Atomic Numbers: the Auto-Zeff Software,” Medical Physics, vol. 39, pp. 1769. Webster, E.A., Jr. and A.M. Kennedy, 1986, Proceedings of the 1986 Flash Radiography Topical (Portland, OR), Columbus, OH: American Society for Nondestructive Testing. Williams, B.G., 1977, Compton Scattering, New York, NY: McGraw Hill. Ying, Z., R. Naidu, and C.R. Crawford, 2006, “Dual Energy Computed Tomography for Explosive Detection,” Journal of X-ray Science and Technology, vol. 14: 235-256. Ying, Z., R. Naidu, K. Guilbert, D. Schafer, and C.R. Crawford, 2007, “Dual Energy Volumetric X-ray Tomographic Sensor for Luggage Screening,” SAS 2007 - IEEE Sensors Applications Symposium, San Diego, CA, pp. 1-6, 6-8 (February). Yun, W. et al., 2006, High Resolution Direct-projection Type X-ray Microtomography System Using Synchrotron or Laboratory-Based X-ray Source, US Patent 7130375, filed 14 January 2005, and issued 31 October 2006. Yun, W. et al., 2008, High Resolution Direct-Projection Type X-ray Microtomography System Using Synchrotron or Laboratory-Based X-ray Source, US Patent 7400704, filed 2 October 2006, and issued 15 July 2008. Zambelli, J., Z. Qi, N. Bevins, and G.H. Chen, 2010, “Quantitative Imaging of Electron Density and Effective Atomic Number Using Phase Contrast CT,” Physics in Medicine and Biology, vol. 55: 6669-6677. CHAPTER 14 ASME Boiler and Pressure Vessel Code: Section VIII, Pressure Vessels, Division 1, “Examination of Steel Castings,” Appendix VII, New York: American Society of Mechanical Engineers. ASNT, 1998, Nondestructive Testing Handbook 3: 2nd edition, Columbus, OH: American Society for Nondestructive Testing. ASTM E94/E94M-17, Standard Guide for Radiographic Examination Using Industrial Radiographic Film, West Conshohocken, PA: ASTM International. ASTM E 155-15, Standard Reference Radiographs for Inspection of Aluminum and Magnesium Castings, West Conshohocken, PA: ASTM International. ASTM E 186-15, Standard Reference Radiographs for Heavy-Walled (2 to 4 1/2-in. [51 to 114-mm]) Steel Castings, West Conshohocken, PA: ASTM International. ASTM E 192-15, Standard Reference Radiographs for Investment Steel Castings of Aerospace Applications, West Conshohocken, PA: ASTM International. ASTM E 272-15, Standard Reference Radiographs for High-Strength CopperBase and Nickel-Copper Alloy Castings, West Conshohocken, PA: ASTM International. ASTM E 280-15, Standard Reference Radiographs for Heavy-Walled (4 1/2 to 12-in. [(114 to 305-mm]) Steel Castings, West Conshohocken, PA: ASTM International. ASTM E 310-15, Standard Reference Radiographs for Tin Bronze Castings, West Conshohocken, PA: ASTM International. ASTM E 390-15, Standard Reference Radiographs for Steel Fusion Welds, West Conshohocken, PA: ASTM International. ASTM E 446-15, Standard Reference Radiographs for Steel Castings Up to 2 in. (51 mm) in Thickness, West Conshohocken, PA: ASTM International. ASTM E 505-15, Standard Reference Radiographs for Inspection of Aluminum and Magnesium Die Castings, West Conshohocken, PA: ASTM International. ASTM E 592-15, Standard Guide to Obtainable ASTM Equivalent Penetrameter Sensitivity for Radiography of Steel Plates 1/4 to 2 in. (6 to 51 mm) Thick with X-Rays and 1 to 6 in. (25 to 152 mm) Thick with Cobalt-60, West Conshohocken, PA: ASTM International. ASTM E 689-15, Standard Reference Radiographs for Ductile Iron Castings, West Conshohocken, PA: ASTM International. ASTM E 746-18, Standard Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems, West Conshohocken, PA: ASTM International. ASTM E 747-04, Standard Practice for Design, Manufacture, and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology, 2010,West Conshohocken, PA: ASTM International. ASTM E 802-15, Standard Reference Radiographs for Gray Iron Castings Up to 4 1/2 in. [114 mm]) in Thickness, West Conshohocken, PA: ASTM International. REFERENCES
Previous Page Next Page